IMPORTANT! Please make sure to run bootloader and update firmware ONLY under Comino professional assistance. You won't be able to undo the operation.
Application |
Run bootloader, update firmware version |
---|---|
How to activate: |
|
If File System is not found, the following messages are shown.
When File System is found
Installing the firmware
Application | Enable or disable calibration at next device start |
---|---|
How to activate: |
|
Application | Erase EEPROM (electrically erasable programmable read-only memory) |
---|---|
How to activate: |
|
Application | Set power limitations for the fans |
---|---|
Possible Values | 0..100% (with 5% step) |
Default Value |
|
How to activate |
|
Application |
Set pulse-width modulation (PWM) lower limit for each fan/pump to check its behaviour in different PWM ranges. Available only in NON-OPERATION modes. |
---|---|
Possible Values | 0..100% (with 1% step) |
How to activate |
|
Application | Set the number of impulses per liter |
---|---|
How to activate: |
|
Application | Set the number of fans (0..6) |
---|---|
How to activate: |
|
Application | Set the number of pumps (0..2) |
---|---|
How to activate: |
|
Application | System autostart after emergency shutdown |
---|---|
Possible Values |
|
Default Value | Disabled |
How to activate |
|
Application | For systems with 1 PSU unit where the controller module is connected to the 6-pin PSU connector. |
---|---|
Possible Values |
|
Default Value | Disabled |
How to activate |
|
Hotkey
When general screens of normal operation (temperature, status, rotation) are displayed, press and hold NEXT>> button to access Temperature Profiles menu.
Regular operation of the device, low noise, increased values of temperature indicators on the GPUs, setting T4set = 45°С. In OPERATION mode, when T4 rises up to 50° or more, the profile is automatically switched to Profile 2: NORMAL
Zero point | Point 1 | Point 2 | Point 3 | Point 4 | Max point | |
---|---|---|---|---|---|---|
Temperature |
0 |
25 |
40 |
50 |
55 |
60 |
PWM | 0 | 15 | 30 | 50 | 100 | 100 |
Zero point | Point 1 | Point 2 | Point 3 | Point 4 | Max point | |
---|---|---|---|---|---|---|
Temperature |
0 |
20 |
35 |
45 |
58 |
60 |
PWM | 15 | 15 | 45 | 75 | 100 | 100 |
Forced operation of all available fans and pumps at 100%.
Zero point | Point 1 | Point 2 | Point 3 | Point 4 | Max point | |
---|---|---|---|---|---|---|
Temperature |
0 |
20 |
40 |
50 |
60 |
70 |
PWM | 100 | 100 | 100 | 100 | 100 | 100 |
The choice of this profile is allowed if T1 and T4 are in their working thresholds. Temperature and PWM points are set by the user in STANDBY mode.
Hold NEXT>> to edit the profile
Press <<PREV or NEXT>> to switch between the profile points (1..4) and see the current value of the temperature setpoint (T2 = YY°C) and the PWM level (PWM = XXX%)
While holding NEXT>>, the PWM and temperature setpoints are set, starting from point 1.
Default setpoints are:
Zero point | Point 1 | Point 2 | Point 3 | Point 4 | Max point | |
---|---|---|---|---|---|---|
Temperature |
0 |
0 |
35 |
45 |
55 |
60 |
PWM | 30 | 30 | 50 | 60 | 100 | 100 |
IMPORTANT! CHANGING TEMPERATURE SETTINGS WILL VOID THE WARRANTY.
Default temperature upper thresholds for INLET & OUTLET AIR are +38ºC and +60ºC. It is highly NOT recommended to change these settings.
Hold NEXT>> button to submit turning off temperature protection.
Press <<PREV or NEXT>> to change the value from 0º to 99º.